Module báo cháy địa chỉ Protec 6000-LCM
Module báo cháy địa chỉ Protec 6000-LCM
Loop Powered Single Zone Fire Alarm • Reduced Incidence of False Alarms in Houses in Multiple Occupation
Local ‘Mute’ facility to Silence Unwanted Alarms
Local‘Disable’ Facility to Isolate Local Detectors and Sounders
Simple One Button Operation
Fully Monitored
Low Current
Integral Short Circuit Isolator
Protec Algo-TecTM 6000 Protocol
Approved to EN54 Part 17 & 18
Description:
The Protec Algo-Tec™ 6000 Local Control Module has been designed to allow easy integration of Protec Addressable Fire Detection systems into Houses in Multiple Occupancy and offers novel features to reduce false and nuisance alarms.
The unit effectively operates as a stand alone fire alarm control panel monitoring detectors and driving sounders in a zone. An automatic detector activation on the zone instigates a search timer to allow the cause of the alarm to be investigated, and dealt with locally, prior to signalling a full alarm to the building fire alarm system.
The unit is loop powered and reports its status back to the master panel at regular intervals.
Operation
The device monitors the detection zone for activations, if one occurs the following decisions are taken.
If the activation is due to an MCP the device will immediately signal a fire condition to the host panel. This will then activate the unit and the local sounders will sound. The Local alarm LED on the unit will be illuminated.
If the activation is due to an automaticdevice being triggered, a ‘search’ time of one minute will be started before the system is put into alarm.
If the mute button is pressed before the search time expires the fire signal to the host panel is delayed by up to 2 minutes. If the zone returns to normal within this time no further action is taken.
If the mute button is pressed prior to an activation an ‘isolated’ period of 15 minutes is instigated. If the mute button is pressed again during the ‘isolated’ period the device returns to normal.
An internal buzzer sounds 15 seconds prior to either the muted or the isolated period expiring.
If the mute button is pressed during the 15 second expiry period the original time-out of 2 or 15 minutes is re-set.
If the master panel has a fire activation the device can be programmed to activate the sounder outputs, this overrides any muted, or isolated state.
Công ty TNHH TM & DV IPCA hân hạnh là nhà cung cấp Báo cháy Protec nhập khẩu chính hãng Anh có đầy đủ CO, CQ và các giấy tờ do cục pccc cấp chúng tôi cam kết chất lượng. Khi mua hàng được chúng tôi cung cấp, quý khách sẽ được bảo đảm về quyền lợi với chế độ bảo hành vô cùng hợp lý. Ngoài cung cấp sản phẩm Thiết bị báo cháy Protec, chúng tôi còn là đơn vị nhập khẩu nhiều hãng báo cháy nổi tiếng trên thế gới.
>>>Tìm hiểu thêm các hệ thống báo cháy khác:
Báo cháy GST, Báo cháy Horing, Báo cháy Chungmei, Báo cháy Siemens, Báo cháy Hochiki, Báo cháy Nittan, Báo cháy Nohmi, Báo cháy notifier, Báo cháy Bosch, Báo cháy Zeta, Báo cháy Protec, Báo cháy YunYang
>>> Liên hệ ngay với Công ty IPCA hoặc gặp trực tiếp bộ phận kinh doanh
Hotline: 0914.348.397 - 0975.907.336 - 0983.04.88.14
Email: tuanthanh@anninh.com.vn - thanhkd.pccc@gmail.com - anninh@anninh.com.vn
Sản phẩm cùng loại
Copyright © 2019 Bản quyền thuộc về CÔNG TY TNHH THƯƠNG MẠI VÀ DỊCH VỤ IPCA Thiết kế và phát triển bởi P.A Việt Nam
Đang Online: 272 | Tổng người online : 2560003